Untitled Document
Product : Coagulation Analyzer
Model : Coatron Series
Maker : TECO GmbH

Home > Products > Coagulation > Coatron Series
 
Intro
COATRON M1
This new manual Coagulation analyzer measures the most important clotting based Coagulation tests with a quarter of the regular volume.

COATRON M2

Reduced reagent and sample volume with same precise and accurate measurements make the routine more cost effective.
This new manual Coagulation analyzer measures all clotting based Coagulation tests with a quarter of the regular volume.

COATRON M4
This new manual Coagulation analyzer measures all clotting based Coagulation tests with a quarter of the regular volume.
A new double-micro cuvette allows for effective and quick work, even for more samples. A unique automatic amplification is especially designed for all new sensitive Thromboplastin reagents and equalizes high differences of turbidity from reagents and samples. All specific test parameters are stored in the system.

COATRON A4
Coatron A4 is designed for the modern, fast and flexible coagulation routine. Ergonomic and function criteria are optimized to a maximum. Reliable and safe detection of the clotting parameters are guaranteed with an intuitive operation. The measure principle to calculate the turning point of the clotting curve is used on all TECO instruments with great success.

DIMEX
The Dimex is a two channel optical instrument designed for the quantitative determination of D-Dimer. The test procedure is optimized for easy handling and quick turnaround time. The accurate and precise results are reported in different selectable dimensions.

TEChrom IV Plus
TEChrom IV plus means a new age in Hemostasis. The TEChrom IV Plus is a semi automated Hemostasis Analyzer, unique in flexibility to measure coagulation parameters (classical clotting tests and chromogenic subrates.)

Point of Product
COATRON M1
The Coatron M1 is a new Coagulation instrument with one optic channel and LC-Display. The tests can be selected after switching on. The dialog language is user friendly and available in English. The start of the measurement will be manually triggered by pressing the "Optic" key during addition of the reagent. An external serial thermal printer can be connected at any time on the prepared RS232 interface.


COATRON M2

The Coefficient of Variation (CV) is < 2 to 5 percent depending on the test and reagent used. A new double cuvette allows for effective and quick work for more samples. A unique automatic amplification is especially designed for all new sensitive Thromboplastin reagents and equalizes high differences of turbidity from reagents and samples. All specific test parameters are stored in the system. The Coatron M2 fits perfectly into small and medium Coagulation laboratories. For usage in Emergency laboratories this instrument offers all possibilities.


COATRON M4
The Coefficient of Variation (CV) is < 2-5% depending on the test and reagent used. A new double-micro cuvette allows for effective, quick work and even more samples. A unique automatic amplification is especially designed for all new sensitive Thromboplastin reagents and equalizes the high differences of turbidity from reagents and samples. All specific test parameters are stored in the system. The Coatron M4 fits perfectly into medium size laboratories.

COATRON A4
Detection system has approved a 4 channel optic (400nm) for coagulmetric, chromogenic or immunological tests and an opti-mised cuvette for optical measurements and half volumes. I.e. for PT: 50uL plasma + 100uL reagent. A positive primary tube detection, a built-in barcode scanner to detect specimen position and ID number. Empty positions will be recognized. STAT-Emergency one STAT position, readable primary barcode scanner Minimum running cost 1,250uL rinse and 250uL Combiclean is sufficient for 1,000 PT/APTT or 2,000 PT. There is less than 200uL dead volume of reagent half volume measurement (total of 150uL). Every cuvette position is used.


DIMEX
The principle of detection is based on the agglutination of D-Dimer antigen in the assay sample, with D-Dimer monoclonal antibody coated latex particles. The rate of agglutination is proportional to the decrease in transmitted laser light. The Dimex utilizes a unique modified kinetic algorithem, which eliminates false results caused by the "High-Dose-Hook-Effect". Results are available within 80 seconds. Either duplicate or single measurements can also be carried out.

TEChrom IV Plus
The TEChrom IV Plus handles 30 different tests separately and individually with all specific calibration data. The TEChrom IV Plus fits perfectly into small and medium size Hemostasis laboratories and works excellent as a Stand-by unit for already installed automated instruments. It is fully suited for usage in Emergency laboratories.




Specification
 
COATRON M1
Device SMD Board, V-25 Microcomputer, 18-bit Analog-Digital Converter, 1 MBit Flash-EPROM; 1 MBit E2 PROM,
Optic block 2-channel Optics
Display 4 lines x 20 Characters, Liquid Crystal Display (LCD)
Incubation block 12 prewarming positions, 2 measuring positions,
3 Reagent position,
Measurement parameters PT, APTT, TT, Fibrinogen (Clauss and PT derived),
Factor II, V, VII, VIII, IX, X, XI, XII, Fletcher, VT (Venom Time),
APCR, AT-III (clot), Protein C (clot), Protein S (clot), Heparin, STAT (PT/PTT)
Important advantages all clotting tests in one system
quarter volume for less price/test
Research capabilities
COATRON M2
Device SMD Board, V-25 Microcomputer, 18-bit Analog-Digital Converter, 1 MBit Flash-EPROM; 1 MBit E2 PROM,
Optic block 4-channel Optics
Display 4 lines x 20 Characters, Liquid Crystal Display (LCD)
Incubation block 24 prewarming positions, 4 measuring positions,
3 Reagent position,
Measurement parameters PT, APTT, TT, Fibrinogen (derived and Clauss), Venom Time,
Factor II, V, VII, VIII, IX, X, XI, XII, STAT (2xPT / 2xAPTT),
AT-III (clot, Protein C (clot), Protein S (clot)
Important advantages All clotting based assays on board
more power for less price
Research capabilities
COATRON M4
Dimensions 245 x 130 x 60 (LxBxH)
Device SMD Board, Microcontroller, 16-bit Analog-Digital Converter
Weight 0,51 kg (w/o Power supply)
Optic block 1 Optic channel
Display 2 lines x 16 Characters, Liquid Crystal Display (LCD)
Incubation block 1 Detection position, 6 Incubation wells
Measurement parameters PT(Prothrombin Time)
APTT(Activated Partial Thromboplastin Time)
TT(Thrombin Time)
FIB(Fibrinogen)
Fa-I(Factor Intrinsic)
Fa-E(Factor Extrinsic)
Important advantages storage capability for ISI, Normal value, Calibration values
quarter volume for less price/test
small and easy handling
COATRON A4
Optic block 4-channel Optics
Display Graphic display
Measurement parameters PT, PTT, TT, Fibrinogen, all Factors, AT-III, Protein C, Protein S (under investigation), APC (under investigation), Hep-Test, D-Dimer (under investigation), Normotest, Thrombotest.
Other specials High throughput of 150 PT/h, 70 PTT/h or 30 profiles
24 loadable patient samples
Positive Bar code identification
Emergency functions (STAT)
Batch and Random Access
Auto dilution (Fib., Factors, etc.)
Auto calibration
Quality Control check
Built-in printer
Host connection available
Research functions
Software-update via Computer and/or Internet
Dimex - D-Dimer
Device SMD Boards, V-25 Microcomputer, 18-bit Analog-Digital Converter, 1 MBit Flash-EPROM, 1 MBit EEPROM
Optic block 2-channel Optics
Display 4 lines x 20 Characters, Liquid Crystal Display (LCD)
Incubation block 12 prewarming positions, 2 measuring positions,
3 Reagent position,
Measurement parameters Quantitative D-Dimer
Important advantages Quick and easy quantitative D-Dimer determination
High precision and accuracy for less price
Research capabilities
Techrom IV plus
Device SMD Boards, V-25 Microcomputer, 18-bit Analog-Digital Converter, 1 MBit Flash-EPROM, 1 MBit E² PROM
Optic block 4-channel Optics with Halogen lamp and light intensity control, 16 different filters possible (coded), Range: 0-2,5 OD linear, up to 3 OD max., Resolution: 1 mOD
Display 4 lines x 20 Characters, Liquid Crystal Display (LCD)
Incubation block 6 Cuvettes prewarming positions, 1 Measuring position,
5 Reagent position,
Measurement parameters PT, APTT, TT, FIB (Clauss/derived), Factor II, V, VII, VIII, IX, X, XI, XII, AT-III, Plasminogen, Heparin, C1-Esterase, Alpha 2-Antiplasmin, Protein C, Protein S,
PAI, tPA, µPA, Heptest, Lupus Anticoagulant, Factor XIII at 340 nm, APCR
D-Dimer and PT-B (whole blood PT) at 710nm,
Research test - free selectable parameters, STAT with 2xPT and 2xAPTT
Important advantages Clotting and chromogenic testing in one system
more power for less price
Research capabilities